top of page

The Solutions

The AnapnoGuard solution provides the clinical staff with the tools to minimize complications while maintaining the highest standards of care in intubated and ventilated patients.

It consists of a platform of automated as well as disposable devices. 

SOLUTION

The AnapnoGuard Solution

Automated ET Tube Cuff Pressure Control

Cuff pressure management, provided by the AnapnoGuard solution, ensures tracheal sealing at the minimum cuff pressure. Appropriate sealing of the trachea, allows for positive pressure ventilation while minimizing aspiration of subglottic secretions and diminishing the likelihood of tracheal tissue injuries, such as mucosal edema, ulceration, fistula, granulomas and injuries to the vocal cords.

The AnapnoGuard solution monitors air leakage from the lungs around the airway cuff, based on continuous measurement of CO2 levels in the subglottic space, above the cuff. High levels of CO2 above the cuff indicate leakage. Therefore, if the system detects a rise in CO2 level above the cuff, it increases the cuff pressure to the minimal pressure needed to ensure tracheal sealing. If no leak is detected, the system decreases the cuff pressure over time, as long as sealing is maintained. The cuff pressure is adjusted within a pressure range that has been predetermined by the clinician.

If the AnapnoGuard AG100s control unit is not available, easy monitoring and adjustment of the ET Tube cuff pressure can be achieved with the manual digital manometer, the AG Cuffill.

Picture1.png
Picture1.png

Effective Evacuation of Subglottic Secretions

The AnapnoGuard solution is designed to ensure effective sealing of the trachea at minimal cuff pressure, while effectively evacuating the subglottic secretions. These functions reduce pulmonary aspiration of subglottic secretions which are known to be a significant contributor to the development of Ventilator-Associated Pneumonia (VAP) and Ventilator-Associated Respiratory Infection (VARI).

The AnapnoGuard ET Tube, comprising of three unique lumens, in conjunction with the AnapnoGuard AG100s control unit, allows simultaneous subglottic rinsing or venting and evacuation of subglottic secretions.

In clinical settings, where the AnapnoGuard AG100s control unit is not available, effective rinsing and suction of the subglottic secretions can be achieved manually with the single-use AG MASS device.

Prod 4
AG 100 Control Unit

The AnapnoGuard solution consists of the following products:

cuffil_hand_trans.png

03

AG CUFFILL

Accurate Cuff Pressure Control Made Easy

The compact and intuitive AG CUFFILL device is the most accurate solution for measuring both pressure and volume of tracheal cuffs in all conditions. Its pocket-size, syringe-like design allows a simple and easy operation by medical professionals, including first-responders and hospital staff, and by users in the home care environment.

 

The AG CUFFILL is designed to enhance patient safety by minimizing the potential of human error while measuring and inflating tracheal cuffs, as well as diminishing the risk of cross-contamination, when used for a single patient.  

cuffilNoHead.png

BENEFITS

Benefits

bullet-01.png

ACCURATE

bullet-01.png

EASY AND INTUITIVE USE

bullet-01.png

SUITABLE FOR ALL AIRWAYS

FEATURES

Features

FEATURE.png

MEASUREMENT RANGE

0-99 (mmHG/cmH2O)

FEATURE.png

MEASUREMENT ACCURACY ±2 (mmHG/cmH2O)

FEATURE.png

VOLUME 10 CC

FEATURE.png

DISPOSABLE, ENABLES 100 MEASUREMENTS

FEATURE.png

POCKET SIZE

US FDA 510(k)   |    European CE Mark   |   China CFDA

bottom of page